Abstract:
T型三电平并网逆变器直流侧电容中性点电压(NP-V)的漂移直接影响并网性能;逆变器并网系统参数的时变及未建模直接影响传统模型预测控制(MPC)精度.为此,本文通过构造不影响NP-V的虚拟中矢量、虚拟补充矢量参与MPC控制矢量集,以克服传统MPC在调制比较高时NP-V不平衡的缺点;建立电流跟踪单目标代价函数,无需整定权重因子;根据直流母线电容状态优选小矢量,进一步控制NP-V平衡;提出一种扩张状态观测器(ESO)观测逆变器并网系统未建模部分,并把观测结果补偿到并网参考电压上.实验结果表明,优化MPC策略消除了NP-V低频振荡,其逆变器输出电流总谐波畸变率(THD)低于传统MPC策略.