• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
成果搜索

author:

Huang, Kailong (Huang, Kailong.) [1] | Zhan, Xu (Zhan, Xu.) [2] | Xue, Tinghui (Xue, Tinghui.) [3] | Chen, Ting (Chen, Ting.) [4] | Liao, Zhengjian (Liao, Zhengjian.) [5] | Luo, Juantao (Luo, Juantao.) [6] | Yi, Zongchao (Yi, Zongchao.) [7] | Hong, Wenyao (Hong, Wenyao.) [8]

Indexed by:

Scopus SCIE

Abstract:

Background: Frontal ventriculostomy (FV) is essential in neurosurgery; however, traditional freehand puncture methods have low accuracy, and ultrasound guidance is time consuming and expensive. To improve freehand puncture accuracy, this study introduced a biplanar intersection (BI) method, and analyzed the frontal-horn puncture mechanism. No related reports exist to date. Methods: Three-dimensional (3D) computed tomography (CT) reconstruction was performed using data from random patients, aged >= 18 years, who presented with enlarged lateral ventricles, and an Evans index >0.33, and had no signs of ventricular compression, deformation, displacement, or a history of craniectomy. This study was conducted at Fujian Provincial Hospital between May 2022 and May 2023. Using the principles of BI, we determined the location coordinates, and conducted a variance analysis. We simulated the puncture using the BI method and compared it with traditional methods. Differences between groups were evaluated using chi-squared tests and independent samples t-tests. Results: A total of 135 patients (110 males, 25 females; aged 18-78 years) were included in the study. The lateral projection was situated 13.3 +/- 1.5 mm anteriorly and 45.7 +/- 4.1 mm superiorly in relation to the intersection of the anterior margin of the tragus and the superior margin of the zygomatic arch. The anterior projection was located 13.8 +/- 2.4 mm above and 5.5 +/- 1.1 mm lateral to the glabella. The mean puncture depth was determined to be 56 mm (48-64 mm). In a sub-analysis of 36 patients, the BI method exhibited a significantly higher optimal puncture rate (36/36 versus 31/36, chi(2)=5.373, P=0.021<0.05) and reduced lateral deviation (2.69 versus 13.97 mm, t=-20.61, P<0.05). Conclusions: The BI method, which is founded on rigorous mathematical principles, was shown through simulations to have enhanced precision in puncture efficiency. However, further clinical research needs to be conducted to ascertain its effectiveness.

Keyword:

biplanar intersection (BI) Frontal ventriculostomy (FV) lateral ventricular puncture (LVP) virtual simulation

Community:

  • [ 1 ] [Huang, Kailong]Fujian Med Univ, Fuzhou Univ Affiliated Prov Hosp, Fujian Prov Hosp, Dept Neurosurg,Shengli Clin Med Coll, 134 East St, Fuzhou 350001, Peoples R China
  • [ 2 ] [Zhan, Xu]Fujian Med Univ, Fuzhou Univ Affiliated Prov Hosp, Fujian Prov Hosp, Dept Neurosurg,Shengli Clin Med Coll, 134 East St, Fuzhou 350001, Peoples R China
  • [ 3 ] [Xue, Tinghui]Fujian Med Univ, Fuzhou Univ Affiliated Prov Hosp, Fujian Prov Hosp, Dept Neurosurg,Shengli Clin Med Coll, 134 East St, Fuzhou 350001, Peoples R China
  • [ 4 ] [Chen, Ting]Fujian Med Univ, Fuzhou Univ Affiliated Prov Hosp, Fujian Prov Hosp, Dept Neurosurg,Shengli Clin Med Coll, 134 East St, Fuzhou 350001, Peoples R China
  • [ 5 ] [Liao, Zhengjian]Fujian Med Univ, Fuzhou Univ Affiliated Prov Hosp, Fujian Prov Hosp, Dept Neurosurg,Shengli Clin Med Coll, 134 East St, Fuzhou 350001, Peoples R China
  • [ 6 ] [Hong, Wenyao]Fujian Med Univ, Fuzhou Univ Affiliated Prov Hosp, Fujian Prov Hosp, Dept Neurosurg,Shengli Clin Med Coll, 134 East St, Fuzhou 350001, Peoples R China
  • [ 7 ] [Huang, Kailong]Fujian Med Univ, Affiliated Hosp 2, Med Diagnost Lab, Clin Med Coll 2, Quanzhou, Peoples R China
  • [ 8 ] [Yi, Zongchao]Hubei Univ Automot Technol, Coll Mech Engn, 167 Checheng West Rd, Shiyan 442002, Peoples R China
  • [ 9 ] [Liao, Zhengjian]Fuzhou Univ, Fujian Engn Res Ctr Joint Intelligent Med Engn, Fuzhou 350108, Peoples R China
  • [ 10 ] [Luo, Juantao]Fuzhou Univ, Fujian Engn Res Ctr Joint Intelligent Med Engn, Fuzhou 350108, Peoples R China
  • [ 11 ] [Hong, Wenyao]Fuzhou Univ, Fujian Engn Res Ctr Joint Intelligent Med Engn, Fuzhou 350108, Peoples R China

Reprint 's Address:

  • [Hong, Wenyao]Fujian Med Univ, Fuzhou Univ Affiliated Prov Hosp, Fujian Prov Hosp, Dept Neurosurg,Shengli Clin Med Coll, 134 East St, Fuzhou 350001, Peoples R China;;[Yi, Zongchao]Hubei Univ Automot Technol, Coll Mech Engn, 167 Checheng West Rd, Shiyan 442002, Peoples R China;;[Hong, Wenyao]Fuzhou Univ, Fujian Engn Res Ctr Joint Intelligent Med Engn, Fuzhou 350108, Peoples R China

Show more details

Related Keywords:

Source :

QUANTITATIVE IMAGING IN MEDICINE AND SURGERY

ISSN: 2223-4292

Year: 2025

Issue: 2

Volume: 15

Page: 1669-1678

2 . 9 0 0

JCR@2023

CAS Journal Grade:3

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 0

Affiliated Colleges:

Online/Total:761/10204463
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1