Liu, Shaofeng (Liu, Shaofeng.) [1] | Liao, Yunyang (Liao, Yunyang.) [2] | He, Bingwei (He, Bingwei.) [3] (Scholars:何炳蔚) | Dai, Bowen (Dai, Bowen.) [4] | Zhu, Zhaoju (Zhu, Zhaoju.) [5] (Scholars:朱兆聚) | Shi, Jiafeng (Shi, Jiafeng.) [6] | Huang, Yue (Huang, Yue.) [7] | Zou, Gengsen (Zou, Gengsen.) [8] | Du, Chen (Du, Chen.) [9] | Shi, Bin (Shi, Bin.) [10]

Indexed by:

Scopus SCIE

Abstract:

The aim of this study was to verify the feasibility and accuracy of a contour registration-based augmented reality (AR) system in jaw surgery.An AR system was developed to display the interaction between virtual planning and images of the surgical site in real time. Several trials were performed with the guidance of the AR system and the surgical guide. The postoperative cone beam CT (CBCT) data were matched with the preoperatively planned data to evaluate the accuracy of the system by comparing the deviations in distance and angle.All procedures were performed successfully. In nine model trials, distance and angular deviations for the mandible, reconstructed fibula, and fixation screws were 1.62 & PLUSMN; 0.38 mm, 1.86 & PLUSMN; 0.43 mm, 1.67 & PLUSMN; 0.70 mm, and 3.68 & PLUSMN; 0.71 & DEG;, 5.48 & PLUSMN; 2.06 & DEG;, 7.50 & PLUSMN; 1.39 & DEG;, respectively. In twelve animal trials, results of the AR system were compared with the surgical guide. Distance deviations for the bilateral condylar outer poles were 0.93 & PLUSMN; 0.63 mm and 0.81 & PLUSMN; 0.30 mm, respectively (p = 0.68). Distance deviations for the bilateral mandibular posterior angles were 2.01 & PLUSMN; 2.49 mm and 2.89 & PLUSMN; 1.83 mm, respectively (p = 0.50). Distance and angular deviations for the mandible were 1.41 & PLUSMN; 0.61 mm, 1.21 & PLUSMN; 0.18 mm (p = 0.45), and 6.81 & PLUSMN; 2.21 & DEG;, 6.11 & PLUSMN; 2.93 & DEG; (p = 0.65), respectively. Distance and angular deviations for the reconstructed tibiofibular bones were 0.88 & PLUSMN; 0.22 mm, 0.84 & PLUSMN; 0.18 mm (p = 0.70), and 6.47 & PLUSMN; 3.03 & DEG;, 6.90 & PLUSMN; 4.01 & DEG; (p = 0.84), respectively.This study proposed a contour registration-based AR system to assist surgeons in intuitively observing the surgical plan intraoperatively. The trial results indicated that this system had similar ac-curacy to the surgical guide.& COPY; 2023 The Authors. Published by Elsevier Ltd on behalf of European Association for Cranio-Maxillo-Facial Surgery. This is an open access article under the CC BY-NC-ND license (http://creativecommons. org/licenses/by-nc-nd/4.0/).

Keyword:

Augmented reality Mandibular surgery Markerless registration Surgery simulation Surgical guide

Community:

  • [ 1 ] [Liu, Shaofeng]Fujian Med Univ, Affiliated Hosp 1, Dept Oral & Maxillofacial Surg, Fuzhou 350005, Peoples R China
  • [ 2 ] [Liao, Yunyang]Fujian Med Univ, Affiliated Hosp 1, Dept Oral & Maxillofacial Surg, Fuzhou 350005, Peoples R China
  • [ 3 ] [Huang, Yue]Fujian Med Univ, Affiliated Hosp 1, Dept Oral & Maxillofacial Surg, Fuzhou 350005, Peoples R China
  • [ 4 ] [Zou, Gengsen]Fujian Med Univ, Affiliated Hosp 1, Dept Oral & Maxillofacial Surg, Fuzhou 350005, Peoples R China
  • [ 5 ] [Du, Chen]Fujian Med Univ, Affiliated Hosp 1, Dept Oral & Maxillofacial Surg, Fuzhou 350005, Peoples R China
  • [ 6 ] [Shi, Bin]Fujian Med Univ, Affiliated Hosp 1, Dept Oral & Maxillofacial Surg, Fuzhou 350005, Peoples R China
  • [ 7 ] [Liu, Shaofeng]Fujian Med Univ, Sch & Hosp Stomatol, Fuzhou 350004, Peoples R China
  • [ 8 ] [Du, Chen]Fujian Med Univ, Sch & Hosp Stomatol, Fuzhou 350004, Peoples R China
  • [ 9 ] [Liao, Yunyang]Fujian Med Univ, Lab Facial Plast & Reconstruct, Fuzhou 350004, Peoples R China
  • [ 10 ] [Huang, Yue]Fujian Med Univ, Lab Facial Plast & Reconstruct, Fuzhou 350004, Peoples R China
  • [ 11 ] [Zou, Gengsen]Fujian Med Univ, Lab Facial Plast & Reconstruct, Fuzhou 350004, Peoples R China
  • [ 12 ] [Shi, Bin]Fujian Med Univ, Lab Facial Plast & Reconstruct, Fuzhou 350004, Peoples R China
  • [ 13 ] [Dai, Bowen]Cent South Univ, Dept Oral & Maxillofacial Surg, Xiangya Hosp 2, Changsha 410000, Peoples R China
  • [ 14 ] [He, Bingwei]Fuzhou Univ, Sch Mech Engn & Automat, Fuzhou 350108, Peoples R China
  • [ 15 ] [Zhu, Zhaoju]Fuzhou Univ, Sch Mech Engn & Automat, Fuzhou 350108, Peoples R China
  • [ 16 ] [Shi, Jiafeng]Fuzhou Univ, Sch Mech Engn & Automat, Fuzhou 350108, Peoples R China
  • [ 17 ] [He, Bingwei]Fujian Engn Res Ctr Joint Intelligent Med Engn, Fuzhou 350108, Peoples R China
  • [ 18 ] [Zhu, Zhaoju]Fujian Engn Res Ctr Joint Intelligent Med Engn, Fuzhou 350108, Peoples R China
  • [ 19 ] [Shi, Jiafeng]Fujian Engn Res Ctr Joint Intelligent Med Engn, Fuzhou 350108, Peoples R China

Reprint 's Address:

Show more details

Related Keywords:

Related Article:

Source :

JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY

ISSN: 1010-5182

Year: 2023

Issue: 6

Volume: 51

Page: 360-368

2 . 1

JCR@2023

2 . 1 0 0

JCR@2023

ESI Discipline: CLINICAL MEDICINE;

ESI HC Threshold:25

JCR Journal Grade:2

CAS Journal Grade:1

Cited Count:

WoS CC Cited Count: 2

SCOPUS Cited Count: 1

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 0

Online/Total:9/10042498
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1