Indexed by:
Abstract:
为研究PC框架节点在地震荷载作用下的破坏模式,设计了2个足尺PC框架梁柱节点,并对其进行拟静力试验。获得了试件破坏形态、极限承载力、滞回曲线和裂缝开展情况等。发现梁叠合面处未出现裂缝,沿梁柱叠合面出现竖向裂缝;轴压比为0.17的试件破坏时,柱叠合面处产生水平裂缝,且节点核心区破坏程度大于轴压比为0.34的试件,轴压比0.34的试件柱叠合面未开裂。研究了2个试件位移延性、承载力退化系数等抗震性能指标,结果表明:PC节点滞回曲线饱满,2个试件延性系数分别为6.56和6.45,承载力退化系数均大于0.85,具有较高延性水平和较好抗震性能。
Keyword:
Reprint 's Address:
Email:
Source :
地震工程与工程振动
Year: 2020
Issue: 03
Volume: 40
Page: 78-84
Cited Count:
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 1
Affiliated Colleges: