Indexed by:
Abstract:
To further improve process economy,Aspen Plus and Aspen Energy Analyzer are used to perform simulation and energy efficiency integration optimization on the process for production of dimethyl sulfide from sulfur-containing waste gas.The optimization results are gained as follows:the minimum heat transfer temperature difference is 13℃; the hot and cold end temperatures of pinch are 77.2℃and 54.2℃,respectively.After optimization,the energy consumption of the hot utility of the whole process decreases by 85.9% and that of cold utility decreases by 63.1%.The simulation and optimization results show that the process has good economy and environmental benefits,and the optimization can provide theoretical guidance for the treatment of sulfur-containing flue gas. © 2019, China National Chemical Information Center. All right reserved.
Keyword:
Reprint 's Address:
Email:
Source :
Modern Chemical Industry
ISSN: 0253-4320
CN: 11-2172/TQ
Year: 2019
Issue: 8
Volume: 39
Page: 221-225
Cited Count:
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 3