author:

Lin, Zhenyu (Lin, Zhenyu.) [1] | Chen, Xiaoping (Chen, Xiaoping.) [2] | Chen, Hongqin (Chen, Hongqin.) [3] | Qiu, Bin (Qiu, Bin.) [4] | Chen, Guonan (Chen, Guonan.) [5]

Indexed by:

EI

Abstract:

A room temperature ionic liquid (IL), 1-butyl-3-methylimidazolium hexafluorophosphate (BMIMPF6) was used as a binder to prepare the electrically heated ionic liquid/carbon paste electrode (IL-HCPE). It has been found that N6-isopentenyl-adenine (2-ip) can enhance the electrochemiluminescent (ECL) intensity of Ru (bpy)32 +. The electrode surface temperature (Te) has great effect on the ECL intensity of Ru (bpy)32 +/2-ip system. The ECL intensities has a linear relationship with the concentration of 2-ip in the range of 1.0 × 10-7-1.2 × 10-6 mol/L with a detection limit of 3.6 × 10-8 mol/L (S/N = 3) when Te was 58 °C, while the linear range was of 5.0 × 10-7-1.0 × 10-6 mol/L with a detection limit of 1.8 × 10-7 mol/L under 27 °C. It was also found that the reproducibility of this ECL system would be better at elevating temperature, the RSD were 7.2% and 1.5% for 8.0 × 10-7 mol/L of 2-ip at 27 and 58 °C, respectively. The possible mechanism of the Ru (bpy)32 +/2-ip ECL system has been proposed also. © 2009 Elsevier B.V. All rights reserved.

Keyword:

Electrodes Ionic liquids Ruthenium

Community:

  • [ 1 ] [Lin, Zhenyu]Ministry of Education Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350002, China
  • [ 2 ] [Chen, Xiaoping]Ministry of Education Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350002, China
  • [ 3 ] [Chen, Hongqin]Ministry of Education Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350002, China
  • [ 4 ] [Qiu, Bin]Ministry of Education Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350002, China
  • [ 5 ] [Chen, Guonan]Ministry of Education Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350002, China

Reprint 's Address:

Show more details

Related Keywords:

Source :

Electrochemistry Communications

ISSN: 1388-2481

Year: 2009

Issue: 10

Volume: 11

Page: 2056-2059

4 . 2 4 3

JCR@2009

4 . 7 0 0

JCR@2023

JCR Journal Grade:1

CAS Journal Grade:1

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count: 15

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 1

Affiliated Colleges:

Online/Total:62/10034368
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1