超高温热泵混合工质性能研究
期刊论文 | 2024 , 43 (01) , 31-37 | 制冷
Abstract&Keyword Cite Version(1)

Abstract :

性能良好的工质是超高温热泵技术开发的关键之一。针对供热温度大于140℃的超高温热泵,根据优势互补的原则,提出了四种性非共沸混合工质MB1、MB2、MB3、MB4,并在蒸发温度50℃、70℃与90℃,冷凝温度140℃-160℃工况下对这四种混合工质的循环性能及最佳配比进行了研究。结果表明,苯,环戊烷,甲苯,丙酮及R13336mzz(Z)可作为该供热温度下热泵的混合工质的组分;四种混合工质性能良好,其中,MB2的循环性能在所提出的混合工质中最优,在蒸发温度50℃,冷凝温度160℃工况下,COP达2.4,?效率达58.9%;在蒸发温度90℃,冷凝温度160℃工况下,COP达4,?效率达62.6%。其它混合工质较主要成分苯的循环性能均有提升,MB4较苯可燃性降低。

Keyword :

供热温度 供热温度 性能系数 性能系数 ?效率 ?效率 混合工质 混合工质 超高温热泵 超高温热泵

Cite:

Copy from the list or Export to your reference management。

GB/T 7714 陈曦 , 刘曦 , 裴依豪 et al. 超高温热泵混合工质性能研究 [J]. | 制冷 , 2024 , 43 (01) : 31-37 .
MLA 陈曦 et al. "超高温热泵混合工质性能研究" . | 制冷 43 . 01 (2024) : 31-37 .
APA 陈曦 , 刘曦 , 裴依豪 , 李学来 . 超高温热泵混合工质性能研究 . | 制冷 , 2024 , 43 (01) , 31-37 .
Export to NoteExpress RIS BibTex

Version :

超高温热泵混合工质性能研究
期刊论文 | 2024 , 43 (1) , 31-37 | 制冷
板式过冷却器内壁面结冰行为的实验研究
期刊论文 | 2023 , 42 (4) , 45-51,57 | 制冷
Abstract&Keyword Cite Version(1)

Abstract :

搭建了一套过冷水制冰系统,实验探究板式过冷却器内壁面结冰行为的关键影响因素.实验结果表明:静止和流动状态下的过冷水结冰均具有较强的随机性,在相同的实验条件下,制冰溶液在过冷却器内出现了3种不同的实验现象.动态制冰时,过高或过低的载冷剂进口温度均会对系统稳定制冰产生不利影响,-6℃是一个较为合适的载冷剂进口温度.系统稳定制冰的关键在于控制壁面温度,载冷剂进口温度和制冰溶液流量均能对换热壁面温度产生影响,且载冷剂进口温度对壁面温度的影响大于制冰溶液流量.相比于流动的制冰溶液,静态的制冰溶液更容易在换热壁面发生结冰.

Keyword :

冰浆 冰浆 壁面结冰 壁面结冰 板式过冷却器 板式过冷却器 结冰行为 结冰行为 过冷水法 过冷水法

Cite:

Copy from the list or Export to your reference management。

GB/T 7714 刘曦 , 范俊杰 , 王震 et al. 板式过冷却器内壁面结冰行为的实验研究 [J]. | 制冷 , 2023 , 42 (4) : 45-51,57 .
MLA 刘曦 et al. "板式过冷却器内壁面结冰行为的实验研究" . | 制冷 42 . 4 (2023) : 45-51,57 .
APA 刘曦 , 范俊杰 , 王震 , 林晨阳 , 陈曦 , 裴依豪 et al. 板式过冷却器内壁面结冰行为的实验研究 . | 制冷 , 2023 , 42 (4) , 45-51,57 .
Export to NoteExpress RIS BibTex

Version :

板式过冷却器内壁面结冰行为的实验研究
期刊论文 | 2023 , 42 (04) , 45-51,57 | 制冷
结构参数对离心式制冷压缩机性能影响的数值分析
期刊论文 | 2022 , 41 (04) , 51-55,60 | 制冷
Abstract&Keyword Cite Version(2)

Abstract :

建立了小流量离心式制冷压缩机内部流动的三维数学模型,并用Krain离心式压气机的实验数据对该模型进行了验证。采用ANSYS CFX软件,调用真实气体模型并读取R134a物性参数,对小流量离心式制冷压缩机内部流动进行了数值模拟。分析了进口叶片角、出口叶片角、相对分流叶片长度等结构参数对压缩机气动性能的影响规律及其内在原因。根据数值分析结果对基于一元流方法设计的原型压缩机结构进行了改进,使其压比提高了使其压比提高了2.68%、等熵效率提高了2.17%。

Keyword :

性能 性能 数值分析 数值分析 离心式制冷压缩机 离心式制冷压缩机 结构参数 结构参数

Cite:

Copy from the list or Export to your reference management。

GB/T 7714 王震 , 范俊杰 , 林晨阳 et al. 结构参数对离心式制冷压缩机性能影响的数值分析 [J]. | 制冷 , 2022 , 41 (04) : 51-55,60 .
MLA 王震 et al. "结构参数对离心式制冷压缩机性能影响的数值分析" . | 制冷 41 . 04 (2022) : 51-55,60 .
APA 王震 , 范俊杰 , 林晨阳 , 刘曦 , 郑闽锋 , 李学来 . 结构参数对离心式制冷压缩机性能影响的数值分析 . | 制冷 , 2022 , 41 (04) , 51-55,60 .
Export to NoteExpress RIS BibTex

Version :

结构参数对离心式制冷压缩机性能影响的数值分析
期刊论文 | 2022 , 41 (04) , 51-55,60 | 制冷
Performance evaluation of CO2 supermarket refrigeration system with multi-ejector and dedicated mechanical subcooling SCIE
期刊论文 | 2021 , 7 , 5214-5227 | ENERGY REPORTS
WoS CC Cited Count: 15
Abstract&Keyword Cite Version(1)

Abstract :

In this paper, a CO2 supermarket refrigeration system using multi-ejector and dedicated mechanical subcooling (MEJ + DMS) is proposed to solve the problem of low performance of the CO2 refrigeration system in high temperature area and evaluate the feasibility application in China. A detailed thermodynamic performance analysis is conducted with MATLAB software. Furthermore, the annual energy consumption and seasonal energy efficiency ratio (SEER) are used as the major indicators to assess the system performance in five typical representative cities of diverse climate types in China. The results indicate that compared with the basic booster system (BASE), the system with dedicated mechanical subcooling (DMS), and that with multi-ejector (MEJ), the MEJ + DMS system permits not only reducing the operating pressure of the system but also enhancing the maximum COP by 61.76%, 19.17% and 20.21%, respectively at the ambient temperature of 40 degrees C. Furthermore, the annual analysis shows that the MEJ + DMS system can save energy by 29.94% and increase SEER by 42.73% in hot summer and warm winter zone. The new proposed system has the advantages of greatly promoting system performance and saving energy and is expected to replace the existing CO2 supermarket booster refrigeration systems. (C) 2021 The Authors. Published by Elsevier Ltd.

Keyword :

CO2 CO2 Dedicated mechanical subcooling Dedicated mechanical subcooling Multi-ejector Multi-ejector Refrigeration Refrigeration Supermarket Supermarket

Cite:

Copy from the list or Export to your reference management。

GB/T 7714 Liu, Xi , Yu, Kaihong , Wan, Xinchen et al. Performance evaluation of CO2 supermarket refrigeration system with multi-ejector and dedicated mechanical subcooling [J]. | ENERGY REPORTS , 2021 , 7 : 5214-5227 .
MLA Liu, Xi et al. "Performance evaluation of CO2 supermarket refrigeration system with multi-ejector and dedicated mechanical subcooling" . | ENERGY REPORTS 7 (2021) : 5214-5227 .
APA Liu, Xi , Yu, Kaihong , Wan, Xinchen , Li, Xuelai . Performance evaluation of CO2 supermarket refrigeration system with multi-ejector and dedicated mechanical subcooling . | ENERGY REPORTS , 2021 , 7 , 5214-5227 .
Export to NoteExpress RIS BibTex

Version :

Performance evaluation of CO2 supermarket refrigeration system with multi-ejector and dedicated mechanical subcooling EI
期刊论文 | 2021 , 7 , 5214-5227 | Energy Reports
Conventional and advanced exergy analyses of transcritical CO2 ejector refrigeration system equipped with thermoelectric subcooler SCIE
期刊论文 | 2021 , 7 , 1765-1779 | ENERGY REPORTS
WoS CC Cited Count: 33
Abstract&Keyword Cite Version(1)

Abstract :

This paper assesses the exergetic performance inside transcritical CO2 ejector refrigeration system integrated with thermoelectric subcooler (EJE + TES) through conventional and advanced exergy analyses. The results point out that 89.44% of the total exergy destruction is endogenous, which clearly demonstrates that it is not close in the interrelations among the system components. In addition, increasing the efficiency of the different components can decrease the exergy destruction by about 53.36%. The avoidable exergy destructions induced by the compressor is the highest, which indicates that priority should be given to the improvement of the compressor, followed by the thermoelectric subcooler, evaporator, ejector and gas cooler, while the expansion valve has almost no potential for improvement. This conclusion differs from that obtained by the conventional exergy method. The effects of the pinch temperature difference in each heat exchanger, as well as the compressor and ejector efficiencies on cycle theoretically exergetic performance are considered. When the compressor and ejector efficiencies increase from 0.5 to 0.9, the avoidable endogenous exergy destruction taking place in the corresponding system component are reduced by 93.61% and 82.33%, respectively. The performance of the EJE + TES system can be enhanced through reducing the pinch temperature difference. (C) 2021 The Authors. Published by Elsevier Ltd.

Keyword :

Advanced exergy analysis Advanced exergy analysis CO2 CO2 Ejector Ejector Thermoelectric subcooler Thermoelectric subcooler Transcritical refrigeration system Transcritical refrigeration system

Cite:

Copy from the list or Export to your reference management。

GB/T 7714 Liu, Xi , Yu, Kaihong , Wan, Xinchen et al. Conventional and advanced exergy analyses of transcritical CO2 ejector refrigeration system equipped with thermoelectric subcooler [J]. | ENERGY REPORTS , 2021 , 7 : 1765-1779 .
MLA Liu, Xi et al. "Conventional and advanced exergy analyses of transcritical CO2 ejector refrigeration system equipped with thermoelectric subcooler" . | ENERGY REPORTS 7 (2021) : 1765-1779 .
APA Liu, Xi , Yu, Kaihong , Wan, Xinchen , Zheng, Minfeng , Li, Xuelai . Conventional and advanced exergy analyses of transcritical CO2 ejector refrigeration system equipped with thermoelectric subcooler . | ENERGY REPORTS , 2021 , 7 , 1765-1779 .
Export to NoteExpress RIS BibTex

Version :

Conventional and advanced exergy analyses of transcritical CO2 ejector refrigeration system equipped with thermoelectric subcooler EI
期刊论文 | 2021 , 7 , 1765-1779 | Energy Reports
小流量离心式压缩机气动性能数值分析
期刊论文 | 2021 , 40 (3) , 18-28 | 制冷
Abstract&Keyword Cite Version(2)

Abstract :

对小流量离心式压缩机内部流动进行了数值模拟,分析了进口叶片角,出口叶片角,叶顶间隙,扩压器出口直径等结构参数对压缩机气动性能的影响,通过内部流场分析探讨了这些参数对气动性能影响的内在机制.分析表明:适当减小叶片入口安装角,适当增大叶片出口安装角,适当减小叶顶间隙,适当减小扩压器出口直径,均可以在一定程度上提升离心压缩机性能.本文研究结果可供小流量离心式的结构优化设计参考.

Cite:

Copy from the list or Export to your reference management。

GB/T 7714 万欣辰 , 郑闽锋 , 刘曦 et al. 小流量离心式压缩机气动性能数值分析 [J]. | 制冷 , 2021 , 40 (3) : 18-28 .
MLA 万欣辰 et al. "小流量离心式压缩机气动性能数值分析" . | 制冷 40 . 3 (2021) : 18-28 .
APA 万欣辰 , 郑闽锋 , 刘曦 , 李学来 . 小流量离心式压缩机气动性能数值分析 . | 制冷 , 2021 , 40 (3) , 18-28 .
Export to NoteExpress RIS BibTex

Version :

小流量离心式压缩机气动性能数值分析
期刊论文 | 2021 , 40 (03) , 18-28 | 制冷
小流量离心式压缩机气动性能数值分析
期刊论文 | 2021 , 40 (03) , 18-28 | 制冷
平板过冷却器内结冰行为的实验研究 CSCD PKU
期刊论文 | 2021 , 42 (04) , 142-148,157 | 制冷学报
Abstract&Keyword Cite Version(2)

Abstract :

本文设计并搭建了一套过冷水动态制冰系统,开发了一种可视化平板过冷却器,通过实验研究流动和换热对过冷却器内结冰行为的影响,并基于经典成核理论与边界层理论对其作用机理进行解释。实验结果表明:平板过冷却器内存在两种典型结冰行为,结冰行为一表现为过冷却器内不结冰,系统可连续制取冰浆;结冰行为二表现为过冷却器内发生结冰,系统不能制取冰浆。载冷剂进口温度过低、制冰溶液流量过大或过小均会促进结冰行为二的出现,不利于系统制冰稳定性。发生结冰行为二时,相对距离d为0.15的壁面优先发生结冰,且该处壁面的温度总低于其余区域,因此优先发生结冰的局部条件是具有更低的壁面温度。

Keyword :

冰浆 冰浆 板式换热器 板式换热器 流动与换热 流动与换热 结冰行为 结冰行为

Cite:

Copy from the list or Export to your reference management。

GB/T 7714 王锦辉 , 郑闽锋 , 李月玲 et al. 平板过冷却器内结冰行为的实验研究 [J]. | 制冷学报 , 2021 , 42 (04) : 142-148,157 .
MLA 王锦辉 et al. "平板过冷却器内结冰行为的实验研究" . | 制冷学报 42 . 04 (2021) : 142-148,157 .
APA 王锦辉 , 郑闽锋 , 李月玲 , 刘曦 , 李学来 . 平板过冷却器内结冰行为的实验研究 . | 制冷学报 , 2021 , 42 (04) , 142-148,157 .
Export to NoteExpress RIS BibTex

Version :

平板过冷却器内结冰行为的实验研究 CSCD PKU
期刊论文 | 2021 , 42 (04) , 142-148,157 | 制冷学报
平板过冷却器内结冰行为的实验研究 CSCD PKU
期刊论文 | 2021 , 42 (4) , 142-148,157 | 制冷学报
超声场对过冷水溶液结晶的影响 CSCD PKU
期刊论文 | 2021 , 42 (5) , 118-126 | 制冷学报
Abstract&Keyword Cite Version(2)

Abstract :

过冷水法动态冰浆制取技术是一种有望实现大规模应用的动态制冰方法,工业上常用施加超声场的方式解除过冷水的过冷态并生成冰浆.本文实验研究了不同超声场对质量分数为3%的氯化钠溶液结晶过冷特性、生成冰晶尺寸及粒径分布的影响.结果表明:一定功率和频率的超声场的引入可快速解除过冷,使溶液在接近超声辐照温度下成核,且高功率、低频率的超声场更有利于成核发生.当功率、频率、辐照温度分别在10.0~40.0 W、28~40 kHz及0~4.0℃范围内,最佳超声场设置方案为超声功率40.0 W、频率28 kHz、辐照温度2.0℃;超声场的施加可显著减小冰晶尺寸;随着成核后超声辐照时间的延长,冰晶粒径先增大后趋于平缓,超声功率及频率的变化对冰晶粒径尺寸的影响无显著作用.

Cite:

Copy from the list or Export to your reference management。

GB/T 7714 刘曦 , 李月玲 , 王锦辉 et al. 超声场对过冷水溶液结晶的影响 [J]. | 制冷学报 , 2021 , 42 (5) : 118-126 .
MLA 刘曦 et al. "超声场对过冷水溶液结晶的影响" . | 制冷学报 42 . 5 (2021) : 118-126 .
APA 刘曦 , 李月玲 , 王锦辉 , 林立 , 李学来 . 超声场对过冷水溶液结晶的影响 . | 制冷学报 , 2021 , 42 (5) , 118-126 .
Export to NoteExpress RIS BibTex

Version :

超声场对过冷水溶液结晶的影响 CSCD PKU
期刊论文 | 2021 , 42 (05) , 118-126 | 制冷学报
超声场对过冷水溶液结晶的影响 CSCD PKU
期刊论文 | 2021 , 42 (05) , 118-126 | 制冷学报
水平管降膜式蒸发器管间流型转换试验研究
期刊论文 | 2020 , 20 (4) , 54-58 | 制冷与空调
Abstract&Keyword Cite Version(2)

Abstract :

为了分析水平管降膜式蒸发器管间流型的转换规律,设计一种多层布液器,采用可视化方法研究开孔规格、布液高度和管间距对管间流型转换的影响.试验结果表明,在一定流量下,流型转换的临界雷诺数与布液孔径、布液孔间距、布液高度、管间距、流动介质有关.根据试验数据拟合得到临界雷诺数Re与伽利略数Ga的关系,发现柱状流到柱-膜状流的过渡区域比较大.

Keyword :

布液器 布液器 水平管 水平管 流型转换 流型转换 蒸发器 蒸发器 降膜 降膜

Cite:

Copy from the list or Export to your reference management。

GB/T 7714 姚宁 , 吴爱华 , 林嘉铭 et al. 水平管降膜式蒸发器管间流型转换试验研究 [J]. | 制冷与空调 , 2020 , 20 (4) : 54-58 .
MLA 姚宁 et al. "水平管降膜式蒸发器管间流型转换试验研究" . | 制冷与空调 20 . 4 (2020) : 54-58 .
APA 姚宁 , 吴爱华 , 林嘉铭 , 胡晟煜 , 张政 , 李学来 . 水平管降膜式蒸发器管间流型转换试验研究 . | 制冷与空调 , 2020 , 20 (4) , 54-58 .
Export to NoteExpress RIS BibTex

Version :

水平管降膜式蒸发器管间流型转换试验研究
期刊论文 | 2020 , 20 (04) , 54-58 | 制冷与空调
水平管降膜式蒸发器管间流型转换试验研究 CQVIP
期刊论文 | 2020 , 20 (4) , 54-58 | 制冷与空调
基于模块化过冷解除的冰浆制取系统实验研究 CSCD PKU
期刊论文 | 2020 , 41 (2) , 56-62 | 制冷学报
Abstract&Keyword Cite Version(2)

Abstract :

过冷水法动态冰浆制取技术具有传热效率高、系统简单等优点,但过冷却器易发生冰堵是影响其稳定性的突出问题.本文提出一种基于模块化过冷解除装置的动态制冰系统,利用设置在过冷却器内的可灵活拆装式螺旋叶片对制冰溶液进行过冷解除,同时刮削换热壁面上粘附的冰晶.测试了不同工况下该制冰系统的性能,结果表明该制冰系统可稳定产出冰浆并有效改善冰堵问题,最高含冰率达9.1%,最大持续制冰时间可达521 s.冰浆含冰率与持续制冰时间成正比.NaCl添加剂质量分数为6%时对冰浆含冰率和持续制冰时间的改善效果显著.实验获得制冰系统最佳运行参数:制冰溶液体积流量为0.50 m3/h、二次冷媒起始温度为-15℃、螺旋叶片转速为175~225 r/min.

Keyword :

冰浆 冰浆 制冰能力 制冰能力 相变 相变 过冷度 过冷度

Cite:

Copy from the list or Export to your reference management。

GB/T 7714 庄焜煜 , 刘曦 , 姚威 et al. 基于模块化过冷解除的冰浆制取系统实验研究 [J]. | 制冷学报 , 2020 , 41 (2) : 56-62 .
MLA 庄焜煜 et al. "基于模块化过冷解除的冰浆制取系统实验研究" . | 制冷学报 41 . 2 (2020) : 56-62 .
APA 庄焜煜 , 刘曦 , 姚威 , 傅阮松 , 王志强 , 李学来 . 基于模块化过冷解除的冰浆制取系统实验研究 . | 制冷学报 , 2020 , 41 (2) , 56-62 .
Export to NoteExpress RIS BibTex

Version :

基于模块化过冷解除的冰浆制取系统实验研究 CQVIP CSCD PKU
期刊论文 | 2020 , 41 (2) , 56-62 | 制冷学报
基于模块化过冷解除的冰浆制取系统实验研究 CSCD PKU
期刊论文 | 2020 , 41 (02) , 56-62 | 制冷学报
10| 20| 50 per page
< Page ,Total 12 >

Export

Results:

Selected

to

Format:
Online/Total:60/10044015
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1