Indexed by:
Abstract:
Based on the design checking method of integral cast-in-place wind tower foundation, considering the stiffness reduction effect and the change of stress characteristics brought by assembly technology, the design checking method of typical assembled fan foundation stress performance is put forward, which includes four aspects: foundation overall stability index, foundation overall bearing capacity index, joint bending performance and joint shear performance. The overall stability index of foundation can be subdivided into six parts: foundation void rate, foundation bearing capacity, foundation settlement, foundation rotation angle, anti-slip and anti-overturning, and the overall bearing capacity index of foundation can be subdivided into bending resistance, shear resistance and punching resistance. Finally, based on Python programming language, the program checking method of typical assembled fan foundation is designed, which realizes the purpose of parametric analysis and instantaneous results. © The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd. 2024.
Keyword:
Reprint 's Address:
Email:
Source :
ISSN: 2366-2557
Year: 2024
Volume: 531 LNCE
Page: 128-140
Language: English
Cited Count:
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 1
Affiliated Colleges: