Abstract:

CFD simulation tests were carried out to study the asymmetric flow phenomenon caused by the combination effect of tunnel slope and longitudinal fire location in a naturally ventilated tunnel. The result shows that the tunnel slope and the longitudinal fire location can both create the induced longitudinal flow solely. The longitudinal flow within tunnel induced by the stack effect caused by the tunnel slope is normally unidirectional, flowing uphill and the speed increases gradually with the tunnel slope. While the longitudinal flow induced by the thermal pressure difference caused by the uneven distribution of upstream and downstream smoke transportation can be bidirectional, which depends on the longitudinal fire location (also known as the downstream and upstream tunnel length difference, ΔL = Ldown − Lup). Therefore, the induced longitudinal flow under the combination effect of tunnel slope and longitudinal fire location is very complex. For tunnels going uphill from left (upstream) to the right (downstream) portals, the two effects are positively added when the fire is located at the upstream tunnel (ΔL > 0), while the two effects are counteracted when the fire is located at the downstream (ΔL © 2024 Elsevier Ltd

Keyword:

Computational fluid dynamics Fires Location Mass transfer Smoke Ventilation

Community:

  • [ 1 ] [Yu, Longxing]College of Environment and Safety Engineering, Fuzhou University, Fuzhou; 350116, China
  • [ 2 ] [Yu, Longxing]State Key Laboratory of Building Safety and Built Environment, China Academy of Building Research, Beijing; 100013, China
  • [ 3 ] [Yu, Longxing]State Key Laboratory of Fire Science, University of Science and Technology of China, JinZhai Road 96, Anhui, Hefei; 230026, China
  • [ 4 ] [Lei, Xiwen]College of Environment and Safety Engineering, Fuzhou University, Fuzhou; 350116, China
  • [ 5 ] [Huang, Ping]College of Environment and Safety Engineering, Fuzhou University, Fuzhou; 350116, China
  • [ 6 ] [Liu, Chunxiang]College of Environment and Safety Engineering, Fuzhou University, Fuzhou; 350116, China
  • [ 7 ] [Zhang, Hao]State Key Laboratory of Building Safety and Built Environment, China Academy of Building Research, Beijing; 100013, China
  • [ 8 ] [Yang, Fuqiang]College of Environment and Safety Engineering, Fuzhou University, Fuzhou; 350116, China

Reprint 's Address:

Email:

Show more details

Related Keywords:

Source :

Tunnelling and Underground Space Technology

ISSN: 0886-7798

Year: 2024

Volume: 146

6 . 7 0 0

JCR@2023

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count: 8

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 0

Affiliated Colleges:

Online/Total:1181/10217157
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1