Aiming at the voltage sag caused by power system fault affects the system many times through electricity-gas coupling equipment, a location and constant volume method of gas storage device in integrated electricity-gas energy system for mitigating voltage sag effect is proposed. The impacts of voltage sags in power system on the integrated electricity-gas energy system are analyzed. Then, the location method of gas storage device in natural gas system is proposed based on the sensitivity analysis. Furthermore, with the comprehensive consideration of investment cost and benefit, the best configuration scheme of gas storage device is determined by taking the maximum benefit after installing gas storage device as the objective function. The correctness and effectiveness of the mitigation method are verified by analyzing an example of the integrated electricity-gas energy system composed of IEEE 14-bus power system and 11-node natural gas system. © 2022, Electric Power Automation Equipment Press. All right reserved.