• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
成果搜索

author:

Zhang, Xiaotao (Zhang, Xiaotao.) [1] | Wei, Yi (Wei, Yi.) [2] | Wu, Huihuang (Wu, Huihuang.) [3] | Yan, Hongli (Yan, Hongli.) [4] | Liu, Yiming (Liu, Yiming.) [5] | Vasic, Zeljka Lucev (Vasic, Zeljka Lucev.) [6] | Pan, Haibo (Pan, Haibo.) [7] (Scholars:潘海波) | Cifrek, Mario (Cifrek, Mario.) [8] | Du, Min (Du, Min.) [9] | Gao, Yueming (Gao, Yueming.) [10] (Scholars:高跃明)

Indexed by:

Scopus SCIE

Abstract:

On-site quantitative detection provides the opportunity for accurate and timely health care, clinical diagnosis, environmental monitoring, and food analysis. A variety of portable electrochemical detection instruments have been developed at present for on-site quantitative detection use, including commercially available portable potentiostats, but the reality is that these electrochemical detection devices still have the problem of narrow output voltage range and detection current range, and their performance of output voltage resolution and detection current resolution is still unsatisfactory. The narrow voltage or current range makes it difficult for some chemical reactions with peaks outside the range to proceed, and the insufficiency of voltage resolution and detection current resolution are key parameters restricting the detection accuracy of existing devices. In this regard, it is urgent to carry out partial transformation of the existing device to increase the use range and detection accuracy of the device. In the current work, a smartphone-based electrochemical on-site quantitative detection device was developed. The device comprises a portable small potentiostat, a smartphone equipped with a specially designed Android electrochemical detection application, and a disposable sensor (NiONP modified screen-printed electrode [SPE]). The potentiostat can realize electrochemical detection methods, including cyclic voltammetry, chronoamperometry, and differential pulse voltammetry. In addition, the potentiostat can output a potential range -2.047 similar to+2.047 V with a current detection sensitivity scale 1x10(-8)similar to 1x10(-3) A, and the current detection range could reach +/- 10 nA similar to +/- 10 mA. Most importantly, the current detection resolution of the potentiostat can reach 0.003 % (3.125 pA on +/- 10 nA range). The smartphone was used for communicating with the potentiostat, setting detection parameters, and mapping voltammograms in real time. The SPE was modified with nickel oxide nanoparticles and perfluorinated resin solution, which were employed as sensors to convert and amplify the electrochemical current response during the on-site quantitative detection. Results indicated that the device features excellent performance for the lactate detection. The device covered a linear range 0.1 similar to 30 mM on lactate detection with the correlation coefficient (R-2) reaching 0.997.

Keyword:

Cyclic voltammetry Nonenzyme Portable potentiostat Screen-printed electrode Smartphone

Community:

  • [ 1 ] [Zhang, Xiaotao]Fuzhou Univ, Coll Phys & Informat Engn, Fuzhou 350108, Peoples R China
  • [ 2 ] [Wei, Yi]Fuzhou Univ, Coll Phys & Informat Engn, Fuzhou 350108, Peoples R China
  • [ 3 ] [Wu, Huihuang]Fuzhou Univ, Coll Phys & Informat Engn, Fuzhou 350108, Peoples R China
  • [ 4 ] [Yan, Hongli]Fuzhou Univ, Coll Phys & Informat Engn, Fuzhou 350108, Peoples R China
  • [ 5 ] [Liu, Yiming]Fuzhou Univ, Coll Phys & Informat Engn, Fuzhou 350108, Peoples R China
  • [ 6 ] [Du, Min]Fuzhou Univ, Coll Phys & Informat Engn, Fuzhou 350108, Peoples R China
  • [ 7 ] [Gao, Yueming]Fuzhou Univ, Coll Phys & Informat Engn, Fuzhou 350108, Peoples R China
  • [ 8 ] [Zhang, Xiaotao]Key Lab Med Instrumentat Pharmaceut Technol Fujia, Fuzhou 350108, Peoples R China
  • [ 9 ] [Wei, Yi]Key Lab Med Instrumentat Pharmaceut Technol Fujia, Fuzhou 350108, Peoples R China
  • [ 10 ] [Wu, Huihuang]Key Lab Med Instrumentat Pharmaceut Technol Fujia, Fuzhou 350108, Peoples R China
  • [ 11 ] [Yan, Hongli]Key Lab Med Instrumentat Pharmaceut Technol Fujia, Fuzhou 350108, Peoples R China
  • [ 12 ] [Liu, Yiming]Key Lab Med Instrumentat Pharmaceut Technol Fujia, Fuzhou 350108, Peoples R China
  • [ 13 ] [Pan, Haibo]Key Lab Med Instrumentat Pharmaceut Technol Fujia, Fuzhou 350108, Peoples R China
  • [ 14 ] [Du, Min]Key Lab Med Instrumentat Pharmaceut Technol Fujia, Fuzhou 350108, Peoples R China
  • [ 15 ] [Gao, Yueming]Key Lab Med Instrumentat Pharmaceut Technol Fujia, Fuzhou 350108, Peoples R China
  • [ 16 ] [Pan, Haibo]Fuzhou Univ, Coll Chem, Fuzhou 350108, Peoples R China
  • [ 17 ] [Vasic, Zeljka Lucev]Univ Zagreb, Fac Elect Engn & Comp, Zagreb 10000, Croatia
  • [ 18 ] [Cifrek, Mario]Univ Zagreb, Fac Elect Engn & Comp, Zagreb 10000, Croatia

Reprint 's Address:

Show more details

Related Keywords:

Source :

ELECTROANALYSIS

ISSN: 1040-0397

Year: 2022

Issue: 9

Volume: 34

Page: 1411-1421

3 . 0

JCR@2022

2 . 7 0 0

JCR@2023

ESI Discipline: CHEMISTRY;

ESI HC Threshold:74

JCR Journal Grade:2

CAS Journal Grade:4

Cited Count:

WoS CC Cited Count: 5

SCOPUS Cited Count: 4

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 3

Online/Total:339/10761251
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1