Abstract:
To provide an easier solution for the simulation study of serial communication protocols, this paper explores the principle of data engine technology and the way it is applied and constructs a reusable serial protocol emulator architecture based on it. Then the Modbus-RTU communication protocol is analyzed, and the program simulation of Modbus-RTU protocol is implemented in the aforementioned architecture. Finally, the feasibility of this protocol emulator is verified by the serial port modulation tool. © 2022, The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.