当配电网发生单相接地故障时,故障点同侧的暂态零序电流具有一致的主谐振频率,而故障点两侧的电流主谐振频率差异较大。根据这一特征,本文提出了一种基于自适应噪声的完备集合经验模态分解(CEEMDAN)能量相对熵的故障区段定位方法来识别此差异,计算得到熵值最大的区段即可判断为故障区段。经仿真分析,该方法在不同的故障条件下均能定位出故障区段,且不受噪声影响,具有很高的准确性和可靠性。