Translated Title
Brief Discussion on Dealing the STM-64 Level SDH Error Code Caused by Cutting and Connecting Fiber Optic Cable
Translated Abstract
Through checking and researching on the error code alarm of 10G SDH optic-transfer equipment caused by cutting and connecting ifber optic, and studying and analyzing the performance index of Metro 5000 (HUAWEI) equipment’s SL64 plate, the results are combined and summarized. The generation mechanism of RSBBE, RSES, MSBBE, MSES in the optic-ifber link was discussed. The paper explicated how daily cutting and connecting of optic ifber cable can cause error code of optic-link, including how to solve the problem and how to think, providing reference for checking, locating and making resolution to remove this type of optic transfer fault.
Translated Keyword
error code
multiplex section
optic ifber
regenerator section
SDH
Access Number
WF:perioarticalydtx201609017