• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
成果搜索

author:

Chen, Z. (Chen, Z..) [1] | Wang, J. (Wang, J..) [2] | Lin, Z. (Lin, Z..) [3] | Chen, G. (Chen, G..) [4]

Indexed by:

Scopus

Abstract:

In this paper, the electrogenerated chemiluminescence (ECL) behavior of 6-(4-methoxyphenyl)-2-methylimidazo[1,2-a]pyrazin-3(7H)-one (MCLA) at an indium-tin-oxide (ITO) electrode in phosphate buffer solution has been investigated when linear sweep voltammetry was applied. The optimum chemical conditions and electrochemical parameters for this ECL system have been investigated in detail. Under the optimum conditions, it was found that the ECL intensity was linear with the concentration of MCLA in the range of 6.0 × 10-7 to 1.0 × 10-5 mol/L, and its detection limit for MCLA was 2.0 × 10-7 mol/L. The possible mechanism for ECL of MCLA at the ITO electrode was also discussion. Furthermore, it was found that some sophora flavescens, such as matrine and oxymatrine, might enhance the ECL intensity of MCLA. Therefore, it is possible to develop a new ECL method for determination of matrine and oxymatrine. © 2006 Elsevier Ltd. All rights reserved.

Keyword:

6-(4-Methoxyphenyl)-2-methylimidazo[1,2-a]pyrazin-3(7H)-one; Electrogenerated chemiluminescence; Indium-tin-oxide electrode; Matrine; Oxymatrine

Community:

  • [ 1 ] [Chen, Z.]The MOE Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350002, China
  • [ 2 ] [Wang, J.]The MOE Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350002, China
  • [ 3 ] [Lin, Z.]The MOE Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350002, China
  • [ 4 ] [Chen, G.]The MOE Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350002, China

Reprint 's Address:

  • [Chen, G.]The MOE Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350002, China

Show more details

Related Keywords:

Related Article:

Source :

Electrochimica Acta

ISSN: 0013-4686

Year: 2006

Issue: 26

Volume: 51

Page: 5864-5869

2 . 9 5 5

JCR@2006

5 . 5 0 0

JCR@2023

JCR Journal Grade:1

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count: 8

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 1

Affiliated Colleges:

Online/Total:66/10070137
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326