• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
成果搜索

author:

Mao, X.-K. (Mao, X.-K..) [1] | Chen, W. (Chen, W..) [2]

Indexed by:

Scopus PKU CSCD

Abstract:

PCB winding with parallel connection is a good solution to improve current handling capability of high-frequericy power planar transformer. However, uneven current sharing among paralleled PCB layers caused by circumfluent current imposes severe challenges on the winding design. The mechanism and factors affecting the current sharing are analyzed deeply and thoroughly with AC eddy loss model built. The results show that exciting current frequency, PCB trace layout, trace connection schemes, thickness of traces and insulation of parallel PCB winding all have great effects on the winding loss. The design guidelines for parallel PCB winding and systematic programming technique for the loss model are also given. Loss model is verified by the experiments.

Keyword:

Parallel PCB winding; Planar magnetic components; Power conversion; Transformer; Winding loss

Community:

  • [ 1 ] [Mao, X.-K.]College of Electrical Engineering and Automation, Fuzhou University, Fuzhou 350002, China
  • [ 2 ] [Chen, W.]College of Electrical Engineering and Automation, Fuzhou University, Fuzhou 350002, China

Reprint 's Address:

  • [Mao, X.-K.]College of Electrical Engineering and Automation, Fuzhou University, Fuzhou 350002, China

Show more details

Related Keywords:

Related Article:

Source :

Proceedings of the Chinese Society of Electrical Engineering

ISSN: 0258-8013

Year: 2006

Issue: 22

Volume: 26

Page: 167-173

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 1

Affiliated Colleges:

Online/Total:108/10272416
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1