Abstract:

Equivalent linearization of seismic isolation systems is often recommended in modern structural specifications for the purpose of simplification. In this paper, limited conditions specified in equivalent linearization of seismic isolation system are investigated when subjected to seismic loads. A large number of numerical simulations, including both approximate linear and exact nonlinear analyses, are performed using a program specially developed by MATLAB in conjunction with OpenSees. Approximate to exact maximum displacement ratio averaged over seven earthquake ground motions is selected as the evaluation indicator. Results reveal that, although satisfactory estimates can be obtained if the limited conditions are met, the application scope of equivalent linearization of seismic isolation system is significantly restricted. To improve the prediction accuracy of equivalent linear analysis in a wider parameter space, equivalent linear model recommended in codes is modified through introducing a factor, which is related to ductility ratio, post-to-pre yield stiffness ratio and initial period of seismic isolation system. It is demonstrated that the newly proposed equivalent linear model yields more accurate results when compared with other equivalent linear models. © 2014 Elsevier Ltd.

Keyword:

Bilinear behavior; Equivalent damping ratio; Equivalent linear analysis; Equivalent stiffness; Seismic isolation

Community:

  • [ 1 ] [Liu, T.]Department of Architecture, Construction and Conservation, Università IUAV di Venezia, Dorsoduro 2206, Venice 30123, Italy
  • [ 2 ] [Zordan, T.]Department of Building Engineering, Tongji University, Shanghai 200092, China
  • [ 3 ] [Briseghella, B.]College of Civil Engineering, Fuzhou University, Fuzhou, Fujian 350108, China
  • [ 4 ] [Zhang, Q.]Department of Building Engineering, Tongji University, Shanghai 200092, China

Reprint 's Address:

  • [Liu, T.]Department of Architecture, Construction and Conservation, Università IUAV di Venezia, Dorsoduro 2206, Venice 30123, Italy

Show more details

Related Keywords:

Related Article:

Source :

Engineering Structures

ISSN: 0141-0296

Year: 2014

Volume: 61

Page: 113-126

1 . 8 3 8

JCR@2014

5 . 6 0 0

JCR@2023

ESI HC Threshold:184

JCR Journal Grade:1

CAS Journal Grade:2

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count: 34

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 1

Affiliated Colleges:

Online/Total:82/10050979
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1