Home>Results

  • Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
成果搜索

[期刊论文]

Amperometric aptasensor for saxitoxin using a gold electrode modified with carbon nanotubes on a self-assembled monolayer, and methylene blue as an electrochemical indicator probe

Share
Edit Delete 报错

author:

Hou, L. (Hou, L..) [1] | Jiang, L. (Jiang, L..) [2] | Song, Y. (Song, Y..) [3] | Unfold

Indexed by:

Scopus

Abstract:

A label-free electrochemical aptasensor was developed for selective detection of saxitoxin (STX). It is taking advantage of target-induced conformational change of an STX-specific aptamer when it binds to the toxin. A monolayer of octadecanethiol was deposited on a gold electrode, and then coated with a film of multiwalled carbon nanotubes (MWCNTs) to which the aptamer was covalently conjugated. Methylene blue (MB) was electrostatically anchored on carboxylated MWCNTs and used as the electrochemical indicator that produced a strong differential pulse voltammetric signal in the absence of target (STX). If, however, STX binds to its aptamer, this triggers a conformational change of the aptamer and results in the establishment of a barrier for heterogeneous electron transfer. The oxidation peak current of MB, acquired at −0.27 V (vs. Ag/AgCl), linearly decreases with increasing concentrations of STX in the 0.9 and 30 nM concentration range. The detection limit is 0.38 nM. Marine toxins that maybe present along with STX do not interfere even if they have a similar chemical structure. The assay was applied to the determination of STX in mussels samples and was found to be acceptably accurate. Hence, the method introduced here provides a rapid and sensitive tool for monitoring red tide pollution. [Figure not available: see fulltext.] © 2016, Springer-Verlag Wien.

Keyword:

Aptamer based assay; Carbon nanotubes film electrode; Cyclic voltammetry; Differential pulse voltammetry; Gold-thiol chemistry; Marine toxin; Methylene blue; Mussel analysis

Community:

  • [ 1 ] [Hou, L.]Key Laboratory of Analysis and Detection for Food Safety (Ministry of Education & Fujian Province)
  • [ 2 ] College of Chemistry, Fuzhou University, Fuzhou, 350108, China
  • [ 3 ] [Jiang, L.]Key Laboratory of Analysis and Detection for Food Safety (Ministry of Education & Fujian Province)
  • [ 4 ] College of Chemistry, Fuzhou University, Fuzhou, 350108, China
  • [ 5 ] [Song, Y.]Key Laboratory of Analysis and Detection for Food Safety (Ministry of Education & Fujian Province)
  • [ 6 ] College of Chemistry, Fuzhou University, Fuzhou, 350108, China
  • [ 7 ] [Ding, Y.]Key Laboratory of Analysis and Detection for Food Safety (Ministry of Education & Fujian Province)
  • [ 8 ] College of Chemistry, Fuzhou University, Fuzhou, 350108, China
  • [ 9 ] [Zhang, J.]Radiation Environment Supervision Station of Fujian Province, Fuzhou, 350000, China
  • [ 10 ] [Wu, X.]Key Laboratory of Analysis and Detection for Food Safety (Ministry of Education & Fujian Province)
  • [ 11 ] College of Chemistry, Fuzhou University, Fuzhou, 350108, China
  • [ 12 ] [Tang, D.]Key Laboratory of Analysis and Detection for Food Safety (Ministry of Education & Fujian Province)
  • [ 13 ] College of Chemistry, Fuzhou University, Fuzhou, 350108, China

Reprint 's Address:

  • [Wu, X.]Key Laboratory of Analysis and Detection for Food Safety (Ministry of Education & Fujian Province); College of Chemistry, Fuzhou UniversityChina

Show more details

Source :

Microchimica Acta

ISSN: 0026-3672

Year: 2016

Issue: 6

Volume: 183

Page: 1971-1980

4 . 5 8

JCR@2016

5 . 4 0 0

JCR@2023

ESI HC Threshold:235

JCR Journal Grade:1

CAS Journal Grade:2

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count: 60

30 Days PV: 1

Affiliated Colleges:

Online/Total:109/10818755
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1