• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
成果搜索

author:

Gan, Z. (Gan, Z..) [1] | Xiong, B. (Xiong, B..) [2] | Du, M. (Du, M..) [3] | Gao, Y. (Gao, Y..) [4] (Scholars:高跃明) | Yang, P. (Yang, P..) [5]

Indexed by:

Scopus PKU CSCD

Abstract:

The large relative error between the measurements and the fitted values with the least squares method easily occurred when the small outputs of CCD. According to this problem, the evaluation method with minimizing the value of the maximum relative error was proposed to solve the optimum curve fitting with the neural dynamic optimization algorithm. Firstly, the CCD opto-electronic responses were achieved by using the high power LED as a linear light source, and the polynomial fitting error model was advanced. Then the neural dynamic optimization algorithm was used to solve it. The experimental results show that the optimum algorithm is stable and effective, and the maximum relative error is not more than 2.5% in the third order polynomial fitting with the neural dynamics. The relative error is obviously reduced in comparison with the least square method. By analyzing the responses, the CCD ICX694AL is with linear characteristics in the unsaturated region. However, it has obvious nonlinear effects in the saturated region. © 2016, Editorial Office of Opto-Electronic Engineering. All right reserved.

Keyword:

CCD; Least square method; Neural dynamics; Opto-electronic response; Relative error

Community:

  • [ 1 ] [Gan, Z.]College of Electrical Engineering and Automation, Fuzhou University, Fuzhou, 350116, China
  • [ 2 ] [Gan, Z.]Key Lab of Medical Instrumentation & Pharmaceutical Technology of Fujian Province, Fuzhou, 350116, China
  • [ 3 ] [Xiong, B.]College of Physics and Information Engineering, Fuzhou University, Fuzhou, 350116, China
  • [ 4 ] [Xiong, B.]Key Lab of Medical Instrumentation & Pharmaceutical Technology of Fujian Province, Fuzhou, 350116, China
  • [ 5 ] [Du, M.]College of Electrical Engineering and Automation, Fuzhou University, Fuzhou, 350116, China
  • [ 6 ] [Du, M.]Key Lab of Medical Instrumentation & Pharmaceutical Technology of Fujian Province, Fuzhou, 350116, China
  • [ 7 ] [Gao, Y.]College of Physics and Information Engineering, Fuzhou University, Fuzhou, 350116, China
  • [ 8 ] [Gao, Y.]Key Lab of Medical Instrumentation & Pharmaceutical Technology of Fujian Province, Fuzhou, 350116, China
  • [ 9 ] [Yang, P.]College of Physics and Information Engineering, Fuzhou University, Fuzhou, 350116, China
  • [ 10 ] [Yang, P.]Key Lab of Medical Instrumentation & Pharmaceutical Technology of Fujian Province, Fuzhou, 350116, China

Reprint 's Address:

Email:

Show more details

Related Keywords:

Related Article:

Source :

Opto-Electronic Engineering

ISSN: 1003-501X

CN: 51-1346/O4

Year: 2016

Issue: 12

Volume: 43

Page: 52-57

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count: 6

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 1

Online/Total:151/10028599
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1