Abstract:

Axial stiffness and flexural stiffness of concrete - filled steel tubes after exposure to fire are very important parameters for the seismic analysis of this kind of structure after fire. A kind of numerical method is used to calculate the load versus deformation curves of axially - loaded and pure flexural members of concrete filled steel tube after exposure to ISO - 834 standard fire. Influence of fire duration time, material strength, steel ratio and sectional dimensions on the stiffness is analyzed. Simplified formula for calculating the axial and flexural stiffness of concrete filled steel tube after fire is given based on the parametric analysis, which may be a reference for concrete filled steel tubular structures used in practical engineering.

Keyword:

Axial stiffness; Concrete filled steel tube; Fire; Flexural stiffness

Community:

  • [ 1 ] [Huo, J.-S.]Civil Engineering/Architecture Sch., Fuzhou University, Fuzhou 350002, China
  • [ 2 ] [Han, L.-H.]Civil Engineering/Architecture Sch., Fuzhou University, Fuzhou 350002, China

Reprint 's Address:

  • 霍静思

    [Huo, J.-S.]Civil Engineering/Architecture Sch., Fuzhou University, Fuzhou 350002, China

Email:

Show more details

Related Keywords:

Related Article:

Source :

Journal of Earthquake Engineering and Engineering Vibration

ISSN: 1000-1301

CN: 23-1157/P

Year: 2002

Issue: 5

Volume: 22

Page: 143-151

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 3

Online/Total:153/10271557
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1