Abstract:

This paper presented a finite element procedure, named NFACFST. The behaviors of concrete-filled steel tube columns during the whole period of fire were carried out by considering the fire damage on the strength and displacement of the concrete-filled steel tube columns at every time step. Comparisons on the fire resistance experimental data and calculation results were made, then a good agreement was obtained. Influence of parameters on the fire resistance was analyzed. The parameters were as follows: load, sectional dimension, steel ratio, column slenderness, etc. The achievements may be of reference for the fireproof design of concrete-filled steel tube columns.

Keyword:

Column; Complete analysis; Concrete-filled steel tube; Fire resistance

Community:

  • [ 1 ] [Yang, H.]Sch. of Civil Eng., Harbin Inst. of Technol., Harbin 150090, China
  • [ 2 ] [Han, L.-H.]Coll. of Civil and Arch., Fuzhou Univ., Fuzhou 350002, China

Reprint 's Address:

  • [Yang, H.]Sch. of Civil Eng., Harbin Inst. of Technol., Harbin 150090, China

Email:

Show more details

Related Keywords:

Related Article:

Source :

Journal of Harbin Institute of Technology

ISSN: 0367-6234

Year: 2003

Issue: SUPPL.

Volume: 35

Page: 93-96

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 3

Affiliated Colleges:

Online/Total:90/9985122
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1