Based on the principle of total internal reflection, a new experimental system, in which the sample is close sandwiched between two prisms, was designed to determine the refractive indices of biotissues and homogeneous medium. Some mammalian tissues have been determined at laser wavelengths of 0.488, 0.6328, 1.0795 and 1.3414μm, respectively, and their dispersion equations have been obtained. And the absolute error between the n calculated from the dispersion equation and the measured is within 0.002. By utilizing these dispersion equations, the refractive indices of the tissues can be obtained at any wavelength within the waveband of 0.488-1.3414μm. The method has great reliability and accuracy, and it can be used for measuring the refractive indices of biotissues and any other medium.
Keyword:
Reprint 's Address:
Email:
Version:
Source :
ISSN: 0277-786X
Year: 2002
Volume: 4916
Page: 172-176
Language: English
Cited Count:
SCOPUS Cited Count: 35
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 0