author:
Bai, Honghui
(Bai, Honghui.)
[1]
|
Wang, Fengxiang
(Wang, Fengxiang.)
[2]
|
Yu, Xinhong
(Yu, Xinhong.)
[3]
|
Lin, Guiying
(Lin, Guiying.)
[4]
Unfold
Abstract:
A large amount of calculation is needed when model predictive control (MPC) is implemented in quasi-Z-source inverter (qZSI). To solve this problem, an improved MPC algorithm is applied to the qZSI. The proposed method is based on sector distribution and new voltage vector selection method. It improves the quality of load current and reduces the amount of calculation greatly. The simulation results show that the proposed MPC algorithm has excellent dynamic and static performance. © 2019 IEEE.
Keyword:
Electric inverters
Information management
Model predictive control
Predictive control systems
Conference Name
3rd IEEE Advanced Information Management, Communicates, Electronic and Automation Control Conference, IMCEC 2019
Classification
731.1 Control Systems
Type
ACKNOWLEDGEMENTS This work is supported by National Natural Science Funds of China (Grant No. 51877207) partly by Quanzhou Science and Technology Project (2017T007), and the Scientific Instrument Developing Project of the Chinese Academy of Sciences (Grant No. YZ201611), and the STS Program Supporting Project of Fujian Province (2016T3013).
Access Number