Indexed by:
Abstract:
A parallel inverter based on the duty cycle extended active clamp forward mode inverter with high frequency pulse DC link is proposed. The circuit topology, steady principle, control strategy of three-state discrete pulse modulation (DPM) hysteresis current, current-sharing, and criterions of the key circuit parameters of the parallel inverter are investigated. The parallel inverter is constituted of the N duty cycle extended active clamp forward mode high frequency pulse DC link inverter modules with common outer voltage regulator and separately inner current regulator. A prototype of 3 kVA 27VDC/115V400HzAC parallel inverter has excellent performances such as small bulk, lower weight, high conversion efficiency, high steady precision, fast dynamic response, wide range input voltage, good output voltage waveforms, good current-sharing effect, strong ability for different nature load, and strong over-load and short-circuit ability. The parallel inverter can be used in large power inversion fields.
Keyword:
Reprint 's Address:
Version:
Source :
Transactions of China Electrotechnical Society
ISSN: 1000-6753
CN: 11-2188/TM
Year: 2006
Issue: 1
Volume: 21
Page: 98-103