Home>Results

  • Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
成果搜索

[期刊论文]

Application of voltage response method to condition assessment of power transformer

Share
Edit Delete 报错

author:

Zhang, Tao (Zhang, Tao.) [1] | Cai, Jin-Ding (Cai, Jin-Ding.) [2] | Zhang, Kong-Lin (Zhang, Kong-Lin.) [3]

Indexed by:

EI Scopus PKU CSCD

Abstract:

Power transformer is one of the most important equipment in the power system. Its operating condition affects the reliability of power supply directly. Therefore, in order to guarantee transformer operation safely and reliably, it is necessary to assess condition of power transformer accurately. Return voltage method based on voltage response measurements is still a new non-intrusive diagnosis method for internal insulation aging of transformer. In this paper the technique and application of return voltage measurement and some results of voltage response measurements of several transformers was introduced. Voltage response measurements were performed on various transformers with different voltage grades, various operating periods, different moisture contents and aging degrees on site. Derived moisture contents from return voltage measurement were compared with the corresponding moisture contents obtained from the analysis of oil samples. Based on on-site experiments and theoretical analysis, the criteria for insulation state of transformer are proposed. Moisture condition of transformer insulation can be determined by using return dominant time constant, and a good correlation between aging degree and the return voltage initial slopes of the aged transformers. Field test performed on several transformers, its interpretation of results are also presented, which proves that return voltage measurements can be used as a reliable tool for evaluating moisture content in transformer insulation.

Community:

  • [ 1 ] [Zhang, Tao]College of Electrical Engineering and Automation, Fuzhou University, Fuzhou 350108, China
  • [ 2 ] [Cai, Jin-Ding]College of Electrical Engineering and Automation, Fuzhou University, Fuzhou 350108, China
  • [ 3 ] [Zhang, Kong-Lin]Fujian Electric Power Testing and Research Institute, Fuzhou 350007, China

Reprint 's Address:

Show more details

Source :

High Voltage Engineering

ISSN: 1003-6520

CN: 42-1239/TM

Year: 2008

Issue: 12

Volume: 34

Page: 2674-2680

Cited Count:

WoS CC Cited Count:

30 Days PV: 0

Online/Total:84/10397854
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1