Indexed by:
Abstract:
In this paper, eight reinforced concrete (RC) beam to concrete-filled steel tubular (CFST) column joints enclosed by rebars were tested under reversal horizontal displacement with constant axial load in order to study their seismic behavior. The test parameters are axial load level and the section type of CFST column. In this study, the failure model, hysteretic characteristic, ductility and energy dissipation were investigated. The results indicated that the anti-earthquake abilities of all joints satisfied with the demand on the code.
Keyword:
Reprint 's Address:
Email:
Version:
Source :
Key Engineering Materials
ISSN: 1013-9826
Year: 2009
Volume: 400-402
Page: 685-691
0 . 2 2 4
JCR@2005
Cited Count:
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 2
Affiliated Colleges: