• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
成果搜索

author:

Yan, Zhiming (Yan, Zhiming.) [1] | Zheng, Jiangnan (Zheng, Jiangnan.) [2] | Chen, Jinfeng (Chen, Jinfeng.) [3] | Tong, Ping (Tong, Ping.) [4] | Lu, Minghua (Lu, Minghua.) [5] | Lin, Zian (Lin, Zian.) [6] | Zhang, Lan (Zhang, Lan.) [7]

Indexed by:

EI

Abstract:

A silica-UIO-66 composite was fabricated by a simple hydrothermal method and then applied as liquid chromatographic stationary phase for fast and efficient separation. X-ray diffraction patterns showed the presence of UIO-66 crystals in the silica-UIO-66 composites; while scanning electron microscope (SEM) images revealed that silica-UIO-66 composites were a homogeneous mixture of silica bead and UIO-66 crystals. A variety of substituted aromatics, chlorobenzene compounds and polycyclic aromatic hydrocarbons (PAHs) were used to evaluate the retention properties of the silica-UIO-66 composite packed column. Under the optimized conditions, baseline separation of ethylbenzene (EB) and styrene was obtained with high resolution and short retention time. In addition, the silica-UIO-66 composite packed column also showed some advantages in separation of positional isomers, with which baseline separation of EB and xylene, chlorotoluene and dichlorobenzene isomers was achieved. Moreover, the retention mechanisms of these compounds were also discussed in detail. The relative standard deviations (RSDs) for the separation of EB and xylene, chlorotoluene and dichlorobenzene isomers, as well as EB and styrene were 0.42-0.9%, 1.0-1.9%, 0.75-2.0%, and 0.9-2.1% for the retention time, peak area, peak height, and half peak width, respectively. The column efficiencies for EB, p-chlorotoluene, p-dichlorobenzene and styrene were 8780, 9060, 9990 and 5130 plates/m. The successful applications suggested high potentials of silica-MOFs composite as stationary phase for fast and efficient liquid chromatography separation. © 2014 Elsevier B.V.

Keyword:

Crystalline materials High performance liquid chromatography Isomers Liquids Organic polymers Organometallics Polycyclic aromatic hydrocarbons Scanning electron microscopy Separation Silica Styrene Xylene

Community:

  • [ 1 ] [Yan, Zhiming]Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Lab. of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian; 350116, China
  • [ 2 ] [Zheng, Jiangnan]Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Lab. of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian; 350116, China
  • [ 3 ] [Chen, Jinfeng]Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Lab. of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian; 350116, China
  • [ 4 ] [Chen, Jinfeng]Longyan Entry-Exit Inspection and Quarantine Bureau of P.R.C, Longyan/org, Fujian; 364000, China
  • [ 5 ] [Tong, Ping]Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Lab. of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian; 350116, China
  • [ 6 ] [Tong, Ping]Testing Center, The Sport Science Research Center, Fuzhou University, Fuzhou, Fujian; 350002, China
  • [ 7 ] [Lu, Minghua]Testing Center, The Sport Science Research Center, Fuzhou University, Fuzhou, Fujian; 350002, China
  • [ 8 ] [Lin, Zian]Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Lab. of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian; 350116, China
  • [ 9 ] [Zhang, Lan]Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Lab. of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian; 350116, China
  • [ 10 ] [Zhang, Lan]Testing Center, The Sport Science Research Center, Fuzhou University, Fuzhou, Fujian; 350002, China

Reprint 's Address:

  • [lin, zian]ministry of education key laboratory of analysis and detection for food safety, fujian provincial key lab. of analysis and detection technology for food safety, college of chemistry, fuzhou university, fuzhou, fujian; 350116, china

Email:

Show more details

Related Keywords:

Source :

Journal of Chromatography A

ISSN: 0021-9673

Year: 2014

Volume: 1366

Page: 45-53

4 . 1 6 9

JCR@2014

3 . 8 0 0

JCR@2023

ESI HC Threshold:268

JCR Journal Grade:1

CAS Journal Grade:2

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count: 75

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 2

Affiliated Colleges:

Online/Total:28/10138480
Address:FZU Library(No.2 Xuyuan Road, Fuzhou, Fujian, PRC Post Code:350116) Contact Us:0591-22865326
Copyright:FZU Library Technical Support:Beijing Aegean Software Co., Ltd. 闽ICP备05005463号-1