[会议论文]

An experimental study and calculation on the fire resistance of concrete-filled SHS and RHS columns

Share
Edit Delete 报错

author:

Han, LH (Han, LH.) [1] | Xu, L (Xu, L.) [2] | Yang, YF (Yang, YF.) [3]

Indexed by:

CPCI-S

Abstract:

The main objectives of this paper are threefold: firstly, to report a series of fire tests on concrete-filled steel SHS (square hollow section) and RHS (rectangular hollow section) columns with square and rectangular sections. Secondly, to analyze the influence of several parameters, such as fire duration time, sectional dimension, slenderness ratio, load eccentricity ratio, strength of steel and concrete on the residual strength index (RSI) of the composite columns. Finally, to develop formulas for the calculation of the fire resistance and the fire protection. thickness of the concrete-filled steel SHS and RHS columns, such formulas are suitable for incorporation into building codes. The concept of this paper were used to provide data on the necessary fire protection measures for the concrete-filled steel SHS columns used in a high-rise building, Ruifeng, Shangye Building in China.

Keyword:

column concrete-filled SHS or RHS fire protection fire resistance standard fire curve temperature

Community:

  • [ 1 ] Fuzhou Univ, Coll Civil Engn & Architecture, Fujian 350002, Peoples R China

Reprint 's Address:

  • 韩林海

    [Han, LH]Fuzhou Univ, Coll Civil Engn & Architecture, Fujian 350002, Peoples R China

Show more details

Source :

ADVANCES IN STEEL STRUCTURES, VOLS I & II, PROCEEDINGS

Year: 2002

Page: 1135-1142

Language: English

Cited Count:

WoS CC Cited Count:

30 Days PV: 3